Structural membrane
The Millennium Dome, London is a cable net structure that features a double-layer PTFE-coated glass fabric membrane. |
A (non-biological) membrane is a very thin, sheet-like material, such as cling film, soap film or a piece of cloth. Membranes may be used as structural components of tensile structures. A tensile structure is a structure that is stabilised by tension rather than compression. For example, a piece of fabric pulled in opposite directions in a tent or inflatable structure.
Materials that are commonly used as structural membranes include cotton canvas, PVC coated polyester and PTFE coated glass. They may also be formed by foils, films, reinforced films, inflated cushions and so on. For more information see: Architectural fabrics.
These membranes are typically part of a system which makes use of cables, pylons, anchors and so on which force the membrane to adopt a tensioned anticlastic or synclastic form.
From a structural perspective, membranes are extremely thin relative to their span; this means that there are certain stresses – such as those resulting from bending – which they cannot appreciably develop. Membranes are therefore mainly affected by tensile stresses, and for this reason can be employed usefully as materials of construction in which they bear mainly tension forces. Analogously, just like the shortest line between two points is a straight line, so the smoothest possible surface connecting points on a boundary is a membrane - as is seen for example in the form of soap films, which adopt minimum surface shapes.
Membranes can support loads in a similar way that cables do: they adopt a curved catenary shape (generally doubly curved in the case of membranes), and in so doing, distribute uniformly the two-dimensional forces across their cross-sectional areas.
Essentially, membrane action involves tensile and shear stresses: these are planar i.e they act along the membrane, never perpendicular to it.
Membranes remain more stable under load when they are pre-tensioned. An example is an umbrella, in which the material is placed under a curving pre-tension by the outward force of the struts emanating from the central pole. This means they distort less when subsequently blown by the wind.
At 320m in diameter, the Millennium Dome is the largest dome in the world. The pre-stressing applied to its double-layer PTFE-coated glass fabric material is applied by cables (from ground anchors and those supported by pylons) which force the membrane into a dome shape. However, although cable net structures such as the Millennium Dome can adopt an overall domed shape, it should be noted that individual sections are generally flat or anticlastic in form (rather than the synclastic form of compression domes).
One architect who played a leading research and developmental role in pre-stressed fabric structures was the German architect, Frei Otto. His projects included the bandstand for the 1955 Federal Garden Exhibition in Kassel; the twin saddle structures at the entrance to the 1957 Cologne garden exhibition; the 8,000m² German pavilion for the 1967 Montreal Expo in Canada, and the plexi glass-clad cable net of the 1972 Munich Olympic Stadium.
[edit] Related articles on Designing Buildings Wiki
- Anticlastic.
- Architectural fabrics.
- Buckminster Fuller.
- Deflection.
- ETFE.
- Fabric structures.
- Frei Otto.
- Geodesic dome.
- Hyperbolic paraboloid.
- Kinetic facade.
- Khan Shatyr Entertainment Centre.
- London 2012 Olympic Stadium.
- Long span roof.
- Megastructure.
- Millennium Dome.
- Principles of enclosure.
- Structural steelwork.
- Structures at the end of their design life.
- Tensile structures.
- The history of fabric structures.
- The structural behaviour of architectural fabric structures.
- The thermal behaviour of spaces enclosed by fabric membranes.
- Types of dome.
Featured articles and news
Designing for neurodiversity: driving change for the better
Accessible inclusive design translated into reality.
RIBA detailed response to Grenfell Inquiry Phase 2 report
Briefing notes following its initial 4 September response.
Approved Document B: Fire Safety from March
Current and future changes with historical documentation.
A New Year, a new look for BSRIA
As phase 1 of the BSRIA Living Laboratory is completed.
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from constructuon and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.
The increasing costs of repair and remediation
Highlighted by regulator of social housing, as acceleration plan continues.
Free topic guide on mould in buildings
The new TG 26/2024 published by BSRIA.
Greater control for LAs over private rental selective licensing
A brief explanation of changes with the NRLA response.
Practice costs for architectural technologists
Salary standards and working out what you’re worth.
The Health and Safety Executive at 50
And over 200 years of Operational Safety and Health.
Thermal imaging surveys a brief intro
Thermal Imaging of Buildings; a pocket guide BG 72/2017.