Draughts in buildings
See also: Draught proofing and air draught.
Contents |
[edit] Introduction
A draught is a noticeable current of air inside a building and can make its occupants uncomfortable. Draught is the UK English spelling, the US English spelling, is ‘draft’, although in the UK this means to prepare text or drawings. The word ‘draught’ is thought to derive from the Old Norse ‘dráttr’ meaning to draw or pull.
Whilst all buildings require ventilation, that is, the replacement of ‘stale’ internal air with ‘fresh’ external air to dilute contaminants, remove moisture and so on, draughts are the uncontrolled supply of air that can be both uncomfortable and costly.
[edit] Causes of draughts
Draughts can be caused by:
- Poorly fitting doors and windows.
- Poor quality or defective windows or doors.
- Open chimneys.
- Defects in dot and dab.
- Ventilated crawl spaces under floors and gaps between floorboards.
- Penetrations through walls such as pipes and wires.
- Letterboxes and key holes.
- Vents in walls.
- Open doors or windows in another part of the building.
- Trickle vents in windows.
- Defective or poorly set up building services.
Draughts can also be experienced where there is a significant change of surface temperature within a building, such as a downdraught felt next to a cold, single-glazed or poor-quality window.
[edit] Indoor air velocities
Generally air velocities inside buildings are relatively low compared to the outside, however it is possible for the range of air velocities to be quite large. There may be entirely stagnant areas where air velocities are close to 0 m/s, whilst in tall spaces or in large mechanically ventilated spaces, internal air velocities can reach several m/s in some places.
Some more typical ranges are set out below:
0 m/s | Stationary air. |
0.1 m/s | The assumed internal air velocity in some simple heat transfer calculations. |
0.1 to 0.15 m/s and above | May be felt as a draught in a cold climate in the winter. |
0.3 m/s and above | May be felt as a draught in a cold climate in the summer. |
0.8 to 1 m/s and above | May be felt as a draught in a hot climate. |
For more information see: Indoor air velocity.
[edit] Air tightness testing
The Air Tightness Testing and Measurement Association (ATTMA) defines ‘air leakage’ as the '...uncontrolled flow of air through gaps and cracks in the fabric of a building. It is sometimes known as infiltration or draughts. Air leakage is not to be confused with ventilation, which is controlled airflow in and out of a building'.
An article on YouGen, suggests that In the typical UK house draughts will account for at least 10% of the total heat loss. If there is an unused open fireplace that figure can rise to more than 50%.
According to the Building Services Research and Information Association (BSRIA), 'Project teams should design and construct the building fabric to be reasonably airtight, and also provide natural or mechanical ventilation systems that maintain good indoor air quality while minimising energy use. In other words: Build tight, ventilate right.' Ref BSRIA Topic Guide - Airtightness.
In England and Wales, airtightness testing has been mandatory for virtually all new buildings since 2006.
See Airtightness testing for more information.
[edit] Remedies
Generally it is possible to feel draughts, however, they can also be detected with thermal detectors or located with candles.
Once located, remedies might include:
- Refurbishing doors and windows.
- Installing secondary or double glazing.
- Installing or repairing weather seals around windows and doors.
- Filling gaps around penetrations through walls.
- Sealing gaps between floor boards.
- Closing gaps in wall constructions.
- Closing off open chimneys (although it is important in this case that the chimney remains vented, both at the top and the bottom, and is filled for example with vermiculite, to prevent the accumulation of moisture).
- Installing or sealing internal doors or other openings to reduce the movement of air within the building.
- Changing operations so that doors remain closed (such as loading bays or receptions).
- Changing building services installations.
However, it is important that intended ventilation paths are not blocked. Air bricks, trickle vents, ventilation to under floor cavities and roof spaces, are provided for a reason, removing or blocking them can cause damp, mould and rot, as well as allowing the build-up of contaminants. Some appliances, such as wood-brining stoves must have ventilation provided if they have an output of more than 4.5kw.
During construction, the overall aim is to ensure the highest quality of workmanship on site. Materials and products in isolation very rarely fail; similarly drawings and specifications rarely fail. Generally, problems arise due to poor workmanship.
See Management and quality control measures for more information.
[edit] Draught risk
Thermal Comfort (TG 22/2023), written by David Bleicher and Calum Maclean and published by BSRIA in 2023 states: ‘The draught risk is a calculated value that incorporates the air speed, air turbulence and air temperature. Draught risk indicates a percentage of people who would be bothered by draught at the point measured.’
[edit] Related articles on Designing Buildings
- Accredited construction details ACDs.
- Achieving sustainable futures with thermal imaging.
- Air change rates.
- Air draught.
- Air permeability testing.
- Air tightness in buildings
- Airtightness of energy efficient buildings.
- Cold bridge.
- Computational fluid dynamics.
- Draught proofing.
- Energy audit.
- Expanding foam.
- Floor plenum airtightness.
- Indoor air quality.
- Indoor air velocity.
- Leaks in buildings.
- Primary air barrier.
- Thermographic survey.
- The history of non-domestic air tightness testing.
Featured articles and news
A briefing on fall protection systems for designers
A legal requirement and an ethical must.
CIOB Ireland launches manifesto for 2024 General Election
A vision for a sustainable, high-quality built environment that benefits all members of society.
Local leaders gain new powers to support local high streets
High Street Rental Auctions to be introduced from December.
Infrastructure sector posts second gain for October
With a boost for housebuilder and commercial developer contract awards.
Sustainable construction design teams survey
Shaping the Future of Sustainable Design: Your Voice Matters.
COP29; impacts of construction and updates
Amid criticism, open letters and calls for reform.
The properties of conservation rooflights
Things to consider when choosing the right product.
Adapting to meet changing needs.
London Build: A festival of construction
Co-located with the London Build Fire & Security Expo.
Tasked with locating groups of 10,000 homes with opportunity.
Delivering radical reform in the UK energy market
What are the benefits, barriers and underlying principles.
Information Management Initiative IMI
Building sector-transforming capabilities in emerging technologies.
Recent study of UK households reveals chilling home truths
Poor insulation, EPC knowledge and lack of understanding as to what retrofit might offer.
Embodied Carbon in the Built Environment
Overview, regulations, detail calculations and much more.
Why the construction sector must embrace workplace mental health support
Let’s talk; more importantly now, than ever.
Ensuring the trustworthiness of AI systems
A key growth area, including impacts for construction.