Overheating in buildings
Contents |
[edit] Introduction
The term 'overheating' refers to discomfort to occupants caused by the accumulation of warmth within a building. It is considered to be a growing problem in the UK due to climate change, the urban heat island effect, electronic equipment, increasing amounts of glazing and so on.
CIBSE define overheating as: 'conditions when the comfortable internal temperature threshold of 28°C is surpassed for over 1% of the time.' They also define 35°C as the internal temperature above which there is a significant danger of heat stress.
In 2006, the Trades Union Congress (TUC) stated that it believed a maximum temperature of 30ºC should be set, or 27ºC for those doing strenuous work. In July 2019, the Labour party proposed the same maximum workplace temperature of 30ºC, or 27ºC for those doing strenuous work. They tasked a proposed Royal Commission on Health and Safety at Work with bringing forward proposals.
For more information see: Heat stress.
Overheating can result in serious health issues, particularly amongst the elderly or young children. The summer heat wave of 2003 recorded an increase of 2,000 deaths in the UK due to heat exposure. It is predicted that by the 2080s this figure could have risen to as much as 5,000.
[edit] Design causes of overheating
Some of the reasons for overheating are thought to be modern building fabric standards that aim to keep buildings warm in colder climates. The House Builder's Association have been reported as saying that 'the ever exacting standards' of Building Regulations Part L cause overheating by stipulating airtightness levels that are too high.
Overheating may be caused by a single predominant factor or as a cumulative effect of different factors. These include:
- Solar radiation passes through glass and heats internal surfaces, which re-radiate long wave infra-red radiation that cannot pass through glass. This is known as the greenhouse effect.
- Double-glazed windows reduce heat losses through conduction.
- Increasingly high levels of insulation reduce heat transmission across the building fabric.
- The activities of occupants such as cooking, bathing, showering all generate heat. Electrical appliances generate heat when in use.
- Occupants themselves generate heat, the amount of which is dependent on their activity level.
- If a site is in close proximity to airborne noise, pollution or odour from busy roads, railways or industrial sites, occupants will be reluctant to open windows and so heat will accumulate inside.
- Urban heat island effect is primarily caused by the replacement of natural surfaces with hard impervious surfaces that are generally dark and absorb large amounts of solar radiation. Urban hard surfaces are significant in the built environment in the form of roads, paved areas, roof tops and so on.
- Buildings oriented with south facing glazing may accumulate high levels of solar gain.
- Overheating problems may be contributed to by heat gain from boilers, hot water storage and distribution and other building services systems. This can be a particular problem in apartment buildings that have community heating pipework.
- Increasing levels of airtightness can reduce the amount of 'fresh' air entering a building.
[edit] How to deal with overheating
- Orientation and footprint can be designed to minimise solar gain and maximise opportunities for cross ventilation, stack ventilation and so on.
- High-performance glazing such as low-e glass, smart glass and so on can reduce heat gains. Smart glazing can be manually or automatically adjusted to control the amount of light, glare or heat that passes through. Whilst the price is decreasing it is still a very expensive option and as such is most likely to be found in commercial developments.
- Adjustable blinds can allow some internal control over solar gains.
- External shading such as canopies, louvres and shutters may help to prevent overheating. Intelligent facades can give control over climate exposure.
- Glazing ratio: Large expanses of glazing increase solar gain and make a building more susceptible to overheating. However, large windows also admit natural light. Glazing ratios try to achieve an equilibrium between these two positions.
For more information, see Preventing overheating.
NB LETI Climate emergency retrofit guide, How existing homes can be adapted to meet UK climate targets, published by LETI in October 2021, defines overheating as: ‘The condition where the internal temperature of a dwelling, typically in summer, spends a certain amount of time above what is considered comfortable. Exact limits vary depending on the standard, but typically anything above 25ºC could be considered overheating.’
[edit] Regulation
Approved Document O was published on 15 December 2021 as part of the government’s plans to deliver net zero. It covers overheating mitigation requirements for new residential buildings:
- Limiting unwanted solar gains in summer.
- Providing an adequate means to remove heat from the indoor environment.
The aim of requirement is to protect the health and welfare of occupants of the building by reducing the occurrence of high indoor temperatures.
For more information see: Approved Document O.
[edit] Related articles on Designing Buildings
- Approved Document O.
- Better prediction of overheating in new homes.
- Comfort in low energy buildings.
- Evolving opportunities for providing thermal comfort.
- Good homes alliance overheating tool
- Heat pumps and heat waves: How overheating complicates ending gas in the UK.
- Heat source.
- Heat stress.
- Heating.
- Heatwave.
- Home Quality Mark high temperature reporting tool.
- Human comfort in buildings.
- Maximum and minimum workplace temperatures.
- Overheating - assessment protocol.
- Overheating in residential properties.
- Preventing overheating.
- Temperature.
- Thermal comfort.
- Thermal indices.
- Thermal pleasure in the built environment.
- Types of heating system.
- Urban heat island.
- When hospital buildings aren’t healthy.
[edit] External references
- Building – Tackling overheating in UK homes
- Zero Carbon Hub – Understanding Overheating
- Research - Overheating in buildings: adaptation responses http://www.tandfonline.com/toc/rbri20/45/1-2
- Overheating in buildings: lessons from research http://www.tandfonline.com/doi/full/10.1080/09613218.2017.1256136
Featured articles and news
A briefing on fall protection systems for designers
A legal requirement and an ethical must.
CIOB Ireland launches manifesto for 2024 General Election
A vision for a sustainable, high-quality built environment that benefits all members of society.
Local leaders gain new powers to support local high streets
High Street Rental Auctions to be introduced from December.
Infrastructure sector posts second gain for October
With a boost for housebuilder and commercial developer contract awards.
Sustainable construction design teams survey
Shaping the Future of Sustainable Design: Your Voice Matters.
COP29; impacts of construction and updates
Amid criticism, open letters and calls for reform.
The properties of conservation rooflights
Things to consider when choosing the right product.
Adapting to meet changing needs.
London Build: A festival of construction
Co-located with the London Build Fire & Security Expo.
Tasked with locating groups of 10,000 homes with opportunity.
Delivering radical reform in the UK energy market
What are the benefits, barriers and underlying principles.
Information Management Initiative IMI
Building sector-transforming capabilities in emerging technologies.
Recent study of UK households reveals chilling home truths
Poor insulation, EPC knowledge and lack of understanding as to what retrofit might offer.
Embodied Carbon in the Built Environment
Overview, regulations, detail calculations and much more.
Why the construction sector must embrace workplace mental health support
Let’s talk; more importantly now, than ever.
Ensuring the trustworthiness of AI systems
A key growth area, including impacts for construction.
Comments