Ventilation
Ventilation is necessary in buildings to remove 'stale' air and replace it with 'fresh' air.
This helps to:
- Moderate internal temperatures.
- Reduce the accumulation of moisture, odours and other gases that can build up during occupied periods.
- Create air movement which improves the comfort of occupants.
Very broadly, ventilation in buildings can be classified as 'natural' or 'mechanical'.
- Mechanical (or 'forced') ventilation tends to be driven by fans.
- Natural ventilation is driven by 'natural' pressure differences from one part of the building to another. Natural ventilation can be wind driven, or buoyancy driven. For more information, see Natural ventilation.
Whilst natural ventilation may be preferable, mechanical ventilation may be necessary where:
- The building is too deep to ventilate from the perimeter.
- Local air quality is poor, for example, if a building is next to a busy road.
- Local noise levels mean that windows cannot be opened.
- The local urban structure is very dense and shelters the building from the wind.
- Air cooling or air conditioning systems mean that windows cannot be opened.
- Privacy or security requirements prevent windows being opened.
- Internal partitions block air paths.
- The creation of draughts adjacent to openings.
NB: Some of these issues can be avoided or mitigated by careful siting and design of buildings.
'Mixed-mode' ventilation uses both natural and mechanical ventilation, for example, allowing the opening of windows, but also providing a mechanical air distribution system.
The term 'assisted ventilation' typically refers to systems where fresh air enters a building through windows or other openings, but is extracted by continuously running fans.
'Trickle ventilation', 'slot ventilators' or 'background' ventilation can be necessary in modern buildings (which tend to be designed to be almost completely sealed from the outside to reduce heat loss or gain), so that problems such as condensation are avoided when openings are closed.
This tendency to 'seal' modern buildings can also adversely affect occupant comfort, as generally, occupants feel more comfortable if there is some air movement (as long as draughts are not created). This situation can be mitigated by heat recovery ventilation (HRV). This permits increased ventilation rates by recovering heat from extract air and using it to pre-heat incoming fresh air using counter-flow heat exchangers. Heat recovery is increasingly common in mechanical ventilation systems. It is also possible, although complicated with some natural ventilation systems.
Ventilation systems may also include heating, cooling, filtration and humidity control. The acronym HVAC refers to Heating Ventilation and Air Conditioning. The phrase 'air conditioning' refers to the process of conditioning the temperature and humidity (and sometimes the quality) of air before using it to ventilate a building. Air conditioning and cooling are not the same, although the terms are often used synonymously by non-professionals.
Rates of ventilation in buildings can be expressed in terms of air change rates (the number of times that the volume of air in a space is changed per hour) or litres per second. The ventilation rate will be determined by the type and size of space and the way it is occupied (for example, the number of occupants, sources of heat, moisture, odour, contaminants, and so on). Ventilation in buildings is regulated by Part F of the Building Regulations.
Whilst there are simple 'rules of thumb' that can be used to design straight-forward ventilation systems, more complex systems may require analysis using environmental design software. Modelling air flow patterns is particularly complex requiring the use of computational fluid dynamics software.
This is complicated further by the interaction of ventilation systems with thermal mass, solar radiation, and so on. Whilst there are software packages that can be used for this sort of analysis, the results they produce are very dependent on the way that models are set up, and this requires a great deal of expertise and experience.
NB Illustrated Guide to Mechanical Cooling (BG 1/2010), written by Kevin Pennycook and published by BSRIA in 2010, states: ‘Ventilation is primarily the supply of fresh air to a building to meet the needs of the occupants - to provide oxygen, dilute carbon dioxide and odours to acceptable levels and remove contaminants. The stale (vitiated) air must also be extracted.’
[edit] Related articles on Designing Buildings
- Air change rates.
- Air conditioning.
- Air handling unit.
- Air infiltration.
- Air infiltration testing.
- Approved Document F.
- Background ventilator.
- Back to the workplace: are you prepared?
- BREEAM Potential for natural ventilation.
- Changes to Building Regulations Part F.
- Computational fluid dynamics.
- Condensation.
- Convection.
- COVID-19 and the US HVAC sector.
- Cross ventilation.
- Designing HVAC to resist harmful microorganisms.
- Dew point.
- Displacement ventilation.
- Domestic ventilation systems performance.
- Effective ventilation in buildings.
- Fresh air.
- Future Buildings Standard shortcomings raised.
- Hatch.
- Heat recovery ventilation.
- Humidity.
- HVAC.
- HVAC balancing.
- Indoor air velocity.
- Locating ventilation inlets to reduce ingress of external pollutants into buildings: A new methodology IP 9 14.
- Mechanical ventilation.
- Mechanical ventilation's role in improving indoor air quality.
- Moisture.
- Natural ventilation.
- Passive building design.
- Preventing overheating.
- Single-sided ventilation.
- Stack effect.
- Standalone: The new way forward in non-domestic ventilation.
- Thermal comfort.
- Underfloor air distribution.
- UV disinfection of building air to remove harmful bacteria and viruses.
- Ventilation and control of COVID-19 transmission.
- Ventilator.
- Whole building ventilation.
Featured articles and news
Designing for neurodiversity: driving change for the better
Accessible inclusive design translated into reality.
RIBA detailed response to Grenfell Inquiry Phase 2 report
Briefing notes following its initial 4 September response.
Approved Document B: Fire Safety from March
Current and future changes with historical documentation.
A New Year, a new look for BSRIA
As phase 1 of the BSRIA Living Laboratory is completed.
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from constructuon and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.
The increasing costs of repair and remediation
Highlighted by regulator of social housing, as acceleration plan continues.
Free topic guide on mould in buildings
The new TG 26/2024 published by BSRIA.
Greater control for LAs over private rental selective licensing
A brief explanation of changes with the NRLA response.
Practice costs for architectural technologists
Salary standards and working out what you’re worth.
The Health and Safety Executive at 50
And over 200 years of Operational Safety and Health.
Thermal imaging surveys a brief intro
Thermal Imaging of Buildings; a pocket guide BG 72/2017.
Comments