The causes of false fire alarms in buildings
A false alarm is a fire alarm signal resulting from a cause, or causes, other than a fire, in which a fire detection and alarm system has responded, such as:
- A fire-like phenomenon or environmental influence (such as smoke from a nearby bonfire).
- Accidental damage.
- Inappropriate human action (such as malicious manual call point (MCP) activation).
- Equipment false alarms, resulting from a fault in the system.
A false alarm becomes an unwanted fire signal (UWFS) when the Fire and Rescue Service (FRS) is requested to attend.
In the period 2011-2012 there were 584,500 alarms reported in Britain. 53.4% of these were not fires and therefore considered “False alarms”. This is a drain on the FRS authorities and causes business disruptions leading to a loss of productivity and reducing the confidence of the general public.
False alarms generated from remotely monitored fire detection and fire alarm systems cost businesses and FRS authorities an estimated £1 billion a year in the UK. Ref London Fire Brigade 2012.
The causes of false fire alarms in buildings was written by R. Chagger, D. Smith and published by BRE Global in 2014. The briefing paper collates information about the causes of false alarms in buildings and identifies approaches to reduce their occurrence.
It was based on data from Kings College London and Buckinghamshire & Milton Keynes Fire Authority. The data supplied provides a snapshot of the types of false alarms that are observed but is not a comprehensive account of what might be the most common causes in the UK.
Kings College London provided data from 699 false alarm incidents and following a thorough review of the data, 6 physical interventions were identified that would address all of the false alarms reported. Replacement of the existing detectors with intelligent multi-sensor detectors (that detect more than one fire phenomena) was the solution that could reduce false alarms the most (by 69%).
Discussions with the Unwanted Fire Signals Officer of Buckinghamshire and Milton Keynes Fire Authority and analysis of their false alarm trends revealed that the use of a technical and experienced individual dedicated to investigating false alarms and engaging directly with regular offenders is a very effective means for FRS’s to reduce false alarms.
However, reducing the number of false alarms from domestic premises remains a challenge despite the fact that the vast majority are reportedly related to cooking incidents. Educating homeowners on effective installation and use of detectors in and around kitchens is likely to lead to the greatest reduction in false alarms from the domestic environment.
The Incident Recording System, used by Fire Officers to report on all callouts attended, lacks sufficient detail to accurately classify false alarm causes. However educating building owners, responsible persons and the general public could contribute significantly to reducing false alarms as simple measures can often cause notable reductions.
In addition, the increased use of multi-sensor detectors may avert false alarms from common causes such as cooking fumes, steam and so on.
[edit] Related articles on Designing Buildings Wiki
- BRE articles on Designing Buildings Wiki.
- Carbon monoxide detector.
- Fire.
- Fire detection and alarm system.
- Fire performance of external thermal insulation for walls of multistorey buildings, third edition (BR 135).
- Fire protection engineering.
- Heat alarm.
- Ionisation smoke alarm.
- Intruder alarm.
- Live investigations of false fire alarms.
- Multi-sensor alarm.
- New requirements for fire detection and alarm network systems IP 12 13.
- Optical smoke alarm.
- Over £1 billion lost every year due to false alarms.
- Project SHOUT.
- Smoke alarm.
- The role of codes, standards and approvals in delivering fire safety.
- Understanding the factors affecting flashover of a fire in modern buildings.
Featured articles and news
CIOB launches global mental health survey
To address the silent mental health crisis in construction.
New categories in sustainability, health and safety, and emerging talent.
Key takeaways from the BSRIA Briefing 2024
Not just waiting for Net Zero, but driving it.
The ISO answer to what is a digital twin
Talking about digital twins in a more consistent manner.
Top tips and risks to look out for.
New Code of Practice for fire and escape door hardware
Published by GAI and DHF.
Retrofit of Buildings, a CIOB Technical Publication
Pertinent technical issues, retrofit measures and the roles involved.
New alliance will tackle skills shortage in greater Manchester
The pioneering Electrotechnical Training and Careers Alliance.
Drone data at the edge: three steps to better AI insights
Offering greater accuracy and quicker access to insights.
From fit-out to higher-risk buildings.
Heritage conservation in Calgary
The triple bottom line.
College of West Anglia apprentice wins SkillELECTRIC gold.
Scottish government launch delivery plan
To strengthen planning and tackle the housing emergency.
How people react in ways which tend to restore their comfort.
Comfort is a crucial missing piece of the puzzle.
ECA launches Recharging Electrical Skills Charter in Wales
Best solutions for the industry and electrical skills in Wales.
New homebuilding skills hub launch and industry response
Working with CITB and NHBC to launch fast track training.