Triple glazing
The term 'glazing' refers to the glass component of a building's façade or internal surfaces. Historically, the installation of glazing was undertaken by a specialist glazier, but today it is possible to purchase entire window units which can be fitted by a general contractor. For more information see: Glazing.
Originally, windows were single glazed, consisting of a single layer of glass. However, a substantial amount of heat is lost through single glazing, and so double glazing was developed, comprising two layers of glass separated by 6-20 mm by a spacer bar creating a cavity filled with air or a gas such as argon. For more information see: Double glazing.
Typically, single glazing can achieve a U-value of around 4.5 W/m²K, whilst the best double glazing can achieve a U-value as low as 1.2 W/m²K. This means that less heat is transmitted through the glazing, and so less energy is required to maintain a comfortable environment inside the building, resulting in lower energy costs and lower carbon emissions.
More recently, super-efficient triple glazing has been developed, comprising three panes of glass separated by spacer bars, and two cavities, generally filled with argon. Triple glazed windows can achieve a U-value of between 0.8 W/m²K and 0.5 W/m²K. This is well below the requirements of the building regulations in England and Wales, which require that windows have a Window Energy Rating (WER) of at least band C or have a U-value of no more than 1.6 W/m²K. However, in some colder parts of northern Europe, triple glazing is the norm, and triple glazing is a requirement of some green rating schemes such as Passivhaus.
As well as energy efficiency, triple glazing can allow improved thermal comfort for the occupants of buildings (by reducing cold spots and eliminating cold downdrafts) as well as better acoustic performance, increased security, reduced solar gain in the summer and a reduction in surface condensation. In combination with other energy saving design features, it can result in noticeable reduction in bills. It may also increase the value of a building.
However, triple glazing is likely to cost around 20% more than double glazing, which in itself is unlikely to be paid back in terms of energy savings in the UK within 10-15 years. This means it is not necessarily an economically justifiable choice as a stand alone design decision. In addition it takes more materials to manufacture (and so has a higher embodied energy). It is also heavier than double glazing and so may require a more substantial supporting structure and is more complex to fit. It also requires great care in manufacture and installation to ensure that designed levels of energy performance are actually achieved on site, and it reduces solar gain in the winter which can increase the amount of heating required.
To a certain extent, whether the benefits outweigh the drawbacks depends on the nature of the installation itself, affected by considerations such as; the extent of glazing in the building, the local climate and degree of exposure, the performance of any existing glazing, the thermal performance of other aspects of the building, and the opportunity cost compared to other potential energy-saving features such as; the installation of a heat pump, super insulation of the walls and roof, improved airtightness and so on.
Alternative approaches to improving the thermal performance of glazing include; wider cavities between the panes of glass (but not so wide as to allow convection), warm spacer bars, low-e coatings, careful design of the frame (to avoid cold bridges, ensure airtightness and introduce insulation), the addition of secondary glazing, careful manufacture and installation and so on.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Heat pumps, vehicle chargers and heating appliances must be sold with smart functionality.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
New-style degrees set for reformed ARB accreditation
Following the ARB Tomorrow's Architects competency outcomes for Architects.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.
Preserving, waterproofing and decorating buildings.
Many resources for visitors aswell as new features for members.
Using technology to empower communities
The Community data platform; capturing the DNA of a place and fostering participation, for better design.
Heat pump and wind turbine sound calculations for PDRs
MCS publish updated sound calculation standards for permitted development installations.
Homes England creates largest housing-led site in the North
Successful, 34 hectare land acquisition with the residential allocation now completed.
Scottish apprenticeship training proposals
General support although better accountability and transparency is sought.
The history of building regulations
A story of belated action in response to crisis.
Moisture, fire safety and emerging trends in living walls
How wet is your wall?
Current policy explained and newly published consultation by the UK and Welsh Governments.
British architecture 1919–39. Book review.
Conservation of listed prefabs in Moseley.
Energy industry calls for urgent reform.