Triple glazing
The term 'glazing' refers to the glass component of a building's façade or internal surfaces. Historically, the installation of glazing was undertaken by a specialist glazier, but today it is possible to purchase entire window units which can be fitted by a general contractor. For more information see: Glazing.
Originally, windows were single glazed, consisting of a single layer of glass. However, a substantial amount of heat is lost through single glazing, and so double glazing was developed, comprising two layers of glass separated by 6-20 mm by a spacer bar creating a cavity filled with air or a gas such as argon. For more information see: Double glazing.
Typically, single glazing can achieve a U-value of around 4.5 W/m²K, whilst the best double glazing can achieve a U-value as low as 1.2 W/m²K. This means that less heat is transmitted through the glazing, and so less energy is required to maintain a comfortable environment inside the building, resulting in lower energy costs and lower carbon emissions.
More recently, super-efficient triple glazing has been developed, comprising three panes of glass separated by spacer bars, and two cavities, generally filled with argon. Triple glazed windows can achieve a U-value of between 0.8 W/m²K and 0.5 W/m²K. This is well below the requirements of the building regulations in England and Wales, which require that windows have a Window Energy Rating (WER) of at least band C or have a U-value of no more than 1.6 W/m²K. However, in some colder parts of northern Europe, triple glazing is the norm, and triple glazing is a requirement of some green rating schemes such as Passivhaus.
As well as energy efficiency, triple glazing can allow improved thermal comfort for the occupants of buildings (by reducing cold spots and eliminating cold downdrafts) as well as better acoustic performance, increased security, reduced solar gain in the summer and a reduction in surface condensation. In combination with other energy saving design features, it can result in noticeable reduction in bills. It may also increase the value of a building.
However, triple glazing is likely to cost around 20% more than double glazing, which in itself is unlikely to be paid back in terms of energy savings in the UK within 10-15 years. This means it is not necessarily an economically justifiable choice as a stand alone design decision. In addition it takes more materials to manufacture (and so has a higher embodied energy). It is also heavier than double glazing and so may require a more substantial supporting structure and is more complex to fit. It also requires great care in manufacture and installation to ensure that designed levels of energy performance are actually achieved on site, and it reduces solar gain in the winter which can increase the amount of heating required.
To a certain extent, whether the benefits outweigh the drawbacks depends on the nature of the installation itself, affected by considerations such as; the extent of glazing in the building, the local climate and degree of exposure, the performance of any existing glazing, the thermal performance of other aspects of the building, and the opportunity cost compared to other potential energy-saving features such as; the installation of a heat pump, super insulation of the walls and roof, improved airtightness and so on.
Alternative approaches to improving the thermal performance of glazing include; wider cavities between the panes of glass (but not so wide as to allow convection), warm spacer bars, low-e coatings, careful design of the frame (to avoid cold bridges, ensure airtightness and introduce insulation), the addition of secondary glazing, careful manufacture and installation and so on.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Twas the site before Christmas...
A rhyme for the industry and a thankyou to our supporters.
Plumbing and heating systems in schools
New apprentice pay rates coming into effect in the new year
Addressing the impact of recent national minimum wage changes.
EBSSA support for the new industry competence structure
The Engineering and Building Services Skills Authority, in working group 2.
Notes from BSRIA Sustainable Futures briefing
From carbon down to the all important customer: Redefining Retrofit for Net Zero Living.
Principal Designer: A New Opportunity for Architects
ACA launches a Principal Designer Register for architects.
A new government plan for housing and nature recovery
Exploring a new housing and infrastructure nature recovery framework.
Leveraging technology to enhance prospects for students
A case study on the significance of the Autodesk Revit certification.
Fundamental Review of Building Regulations Guidance
Announced during commons debate on the Grenfell Inquiry Phase 2 report.
CIAT responds to the updated National Planning Policy Framework
With key changes in the revised NPPF outlined.
Councils and communities highlighted for delivery of common-sense housing in planning overhaul
As government follows up with mandatory housing targets.
CIOB photographic competition final images revealed
Art of Building produces stunning images for another year.
HSE prosecutes company for putting workers at risk
Roofing company fined and its director sentenced.
Strategic restructure to transform industry competence
EBSSA becomes part of a new industry competence structure.
Major overhaul of planning committees proposed by government
Planning decisions set to be fast-tracked to tackle the housing crisis.
Industry Competence Steering Group restructure
ICSG transitions to the Industry Competence Committee (ICC) under the Building Safety Regulator (BSR).
Principal Contractor Competency Certification Scheme
CIOB PCCCS competence framework for Principal Contractors.
The CIAT Principal Designer register
Issues explained via a series of FAQs.