Scaffold register
A scaffold register, or scaffold inspection report, is used to record routine inspections of scaffolding. Among other things, it notes any defects or issues that could pose a health and safety hazard, along with any corrective actions that are taken.
According to the Work at Height Regulations, scaffolding should be inspected:
- Following installation and before the first use.
- At least every seven days thereafter.
- Following significant alteration.
- Following adverse weather or any event that is likely to affect its strength or stability.
It is the responsibility of the scaffold users to ensure that it has been inspected.
The individual who completes the inspection and fills in the register must be a competent person, i.e. a scaffolder or someone who has completed a scaffold inspection course. Tags (also known as scafftags) can be fixed to the scaffold with the details of the last inspection.
Typical scaffold registers might contain the following information:
- Company name and address.
- Site address.
- Location and description of scaffold inspected.
- Date and time of inspection.
- Issues that could pose any health and safety risks.
- Details of any action taken at the time of the inspection.
- Details of any further action considered necessary.
- Name and role of inspector.
- Inspectors signature.
[edit] Related articles on Designing Buildings
Featured articles and news
50th Golden anniversary ECA Edmundson apprentice award
Showcasing the very best electrotechnical and engineering services for half a century.
Welsh government consults on HRBs and reg changes
Seeking feedback on a new regulatory regime and a broad range of issues.
CIOB Client Guide (2nd edition) March 2025
Free download covering statutory dutyholder roles under the Building Safety Act and much more.
AI and automation in 3D modelling and spatial design
Can almost half of design development tasks be automated?
Minister quizzed, as responsibility transfers to MHCLG and BSR publishes new building control guidance.
UK environmental regulations reform 2025
Amid wider new approaches to ensure regulators and regulation support growth.
The maintenance challenge of tenements.
BSRIA Statutory Compliance Inspection Checklist
BG80/2025 now significantly updated to include requirements related to important changes in legislation.
Shortlist for the 2025 Roofscape Design Awards
Talent and innovation showcase announcement from the trussed rafter industry.
OpenUSD possibilities: Look before you leap
Being ready for the OpenUSD solutions set to transform architecture and design.
Global Asbestos Awareness Week 2025
Highlighting the continuing threat to trades persons.
Retrofit of Buildings, a CIOB Technical Publication
Now available in Arabic and Chinese aswell as English.
The context, schemes, standards, roles and relevance of the Building Safety Act.
Retrofit 25 – What's Stopping Us?
Exhibition Opens at The Building Centre.
Types of work to existing buildings
A simple circular economy wiki breakdown with further links.
A threat to the creativity that makes London special.
How can digital twins boost profitability within construction?
The smart construction dashboard, as-built data and site changes forming an accurate digital twin.