Electrical resistance meters
Contents |
[edit] Introduction
When identifying rising damp in buildings, architects, surveyors and other consultants may use moisture meters to confirm or obtain a diagnosis. The most common types of moisture meters are carbide meters and electrical resistance meters.
Carbide meters give an accurate measure of moisture content, although they require the removal of a sample - which could be considered destructive. As a result, this method of testing may only be advisable after an electronic resistance meter or some other method has discovered the presence of moisture.
Electrical resistance meters measure dampness either on the surface, or within the building fabric itself. Generally, if the meter reading indicates that the fabric is dry, then it is dry.
[edit] Wood Moisture Equivalent
Electrical resistance meters were developed for use in timber, and if the reading indicates the fabric is wet, this does not necessarily mean that it is wet, as the presence of other substances such as soluble salts will give a similar reading, and in older walls, salts may be present even where damp is not. When using these meters on materials other than wood, the readings will only indicate the presence of moisture as it relates to the moisture content of timber.
The Wood Moisture Equivalent (WME) is the theoretical moisture content - or moisture profile - that the substrate would contain if it were wood.
[edit] How do electrical resistance meters work?
Moisture meters generate readings based on how easily a small electric current can pass through a designated test area. If the current flows easily, this theoretically indicates the presence of moisture. The wetter the material, the more readily the current will flow.
There are two main types of electrical meters that are used for this process: pinned and pinless:
[edit] Pinned meters
Pinned meters take readings by measuring moisture levels recorded from two to four small probes fixed to the meter. These pins are inserted into the test substance, and then an electrical current is sent through the sample area to record electrical resistance or resistivity. This type of meter takes readings for a very specific area and will require multiple measurements which may be considered destructive (since numerous small holes will be created for each reading).
Taking readings with a pinned meter can generally be broken down into four steps:
- The meter should be set to correspond to the type of material being tested.
- The pins of the meter should be perpendicular to the surface and then pushed as far as safely possible into the sample area.
- The reading should be recorded as either a percentage or reference point.
- The process should be repeated in different areas with a concentration of samples in areas, such as around windows, that may be more prone to moisture.
[edit] Pinless meters
Pinless meters use a sensor pad to send an electromagnetic signal to a designated area to assess whether or not moisture is present in a wider area. The sensor’s wave movement data registers the moisture level when contact is made. This method can read depths up to 1.5 inches and does not require an invasive sample.
Taking readings with a pinless meter can also be broken down into four general steps:
- The surface should be cleared of any debris or standing water before a measurement is taken.
- The meter should be positioned and then pressed against the sample area and held until the reading stabilises.
- The reading of moisture content or percentage value should be recorded.
- The meter can be repositioned in other areas of the surface to determine the extent - if any - of moisture present.
[edit] False readings
There is a possibility that electrical resistance meters could deliver inaccurate readings that may be artificially elevated. These can be caused by a number of factors, including:
- Free water in materials caused by condensation, leaks, penetrating damp and other factors.
- Salts that contaminate materials, such as plaster, mortar, brickwork, wallpaper paste and chimneys.
- Materials with metal content, such as foil backed wallpaper, lead based paints and some timber preservatives that contain heavy metals.
- Materials such as clinker blocks and black ash mortar, used in the construction of older properties in certain parts of the country.
All electrical resistance meters should be calibrated before measurements are taken.
For more information see: Assessing moisture in porous building materials.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Designing for neurodiversity: driving change for the better
Accessible inclusive design translated into reality.
RIBA detailed response to Grenfell Inquiry Phase 2 report
Briefing notes following its initial 4 September response.
Approved Document B: Fire Safety from March
Current and future changes with historical documentation.
A New Year, a new look for BSRIA
As phase 1 of the BSRIA Living Laboratory is completed.
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from constructuon and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.
The increasing costs of repair and remediation
Highlighted by regulator of social housing, as acceleration plan continues.
Free topic guide on mould in buildings
The new TG 26/2024 published by BSRIA.
Greater control for LAs over private rental selective licensing
A brief explanation of changes with the NRLA response.
Practice costs for architectural technologists
Salary standards and working out what you’re worth.
The Health and Safety Executive at 50
And over 200 years of Operational Safety and Health.
Thermal imaging surveys a brief intro
Thermal Imaging of Buildings; a pocket guide BG 72/2017.