Thermal bridging in buildings
A thermal bridge (sometimes referred to as thermal bridging, a cold bridge or thermal bypass) describes a situation in a building where there is a direct connection between the inside and outside through one or more elements that are more thermally conductive than the rest of the building envelope.
As a result, there will be wasteful heat transfer across this element, its internal surface temperature will be different from other, better insulated internal surfaces and there may be condensation where warm, moist internal air comes into contact with the, potentially cold, surface. This condensation can result in mould growth.
Thermal bridges are common in older buildings, which may be poorly constructed, poorly insulated, with single skin construction and single glazing.
In modern buildings, thermal bridging can occur because of poor design, or poor workmanship. This is common where elements of the building penetrate through its insulated fabric, for example around glazing, or where the structure penetrates the building envelope, such as at balconies.
However, as buildings have become better insulated, with increasingly strict regulation, so thermal bridges that might previously have been considered insignificant in terms of the overall thermal performance of a building, can actually be the cause of considerable thermal inefficiency. There is the potential for such inefficiency at every opening and every junction (even in party walls).
Thermal bridges can be categorised as 'repeating' for example where wall ties regularly bridge the cavity, or 'non-repeating' such as a wall junction or lintel.
The Approved Documents to Part L of the building regulations (Conservation of fuel and power) state that 'The building fabric should be constructed so that there are no reasonably avoidable thermal bridges in the insulation layers caused by gaps within the various elements, at the joints between elements and at the edges of elements such as those around window and door openings.'
They require that where unaccredited construction details are used, generic linear thermal bridge values must be increased by levels (depending on the building type) set out in the Approved Documents for the calculations of building emission rates (BER) or dwelling emission rates (DER).
Thermal bridges in completed buildings can be revealed with thermal imaging cameras (see Thermographic survey), but they can be very difficult to rectify, particularly if they are repeated throughout a building.
NB Assessing risks in insulation retrofits using hygrothermal software tools, Heat and moisture transport in internally insulated stone walls, by Joseph Little, Calina Ferraro and Beñat Arregi, published by Historic Environment Scotland in 2015, defines thermal bypass as: ‘Heat transfer that bypasses the conductive or conductive-radiative heat transfer between two regions. It may well be a major contributor to the performance gap that appears to exist between predicted and actual thermal performance. Bypass mechanisms include air leakage, thermal looping, wind washing etc.’
[edit] Related articles on Designing Buildings
- Accredited construction details ACDs.
- Assessing the effects of thermal bridging at junctions and around openings.
- Building fabric.
- Cavity wall.
- Co-heating test.
- Computational fluid dynamics.
- Conventions for calculating linear thermal transmittance and temperature factors.
- Emission rates in the building regulations.
- Floor insulation.
- g-values.
- Insulation for ground floors.
- Insulation specification.
- Interstitial condensation.
- Mould growth.
- Roof insulation.
- Reducing thermal bridging at junctions when designing and installing solid wall insulation FB 61.
- Solid wall insulation.
- Thermal bridging and the Future Homes Standard.
- Thermal comfort.
- Thermal imaging to improve energy efficiency in building design.
- Thermographic survey.
- U-values.
Featured articles and news
Classroom electrician courses a 'waste of money'
Say experts from the Electrical Contractors’ Association.
Wellbeing in Buildings TG 10/2025
BSRIA topic guide updates.
With brief background and WELL v2™.
From studies, to books to a new project, with founder Emma Walshaw.
Types of drawings for building design
Still one of the most popular articles the A-Z of drawings.
Who, or What Does the Building Safety Act Apply To?
From compliance to competence in brief.
The remarkable story of a Highland architect.
Commissioning Responsibilities Framework BG 88/2025
BSRIA guidance on establishing clear roles and responsibilities for commissioning tasks.
An architectural movement to love or hate.
Don’t take British stone for granted
It won’t survive on supplying the heritage sector alone.
The Constructing Excellence Value Toolkit
Driving value-based decision making in construction.
Meet CIOB event in Northern Ireland
Inspiring the next generation of construction talent.
Reasons for using MVHR systems
6 reasons for a whole-house approach to ventilation.
Supplementary Planning Documents, a reminder
As used by the City of London to introduce a Retrofit first policy.
The what, how, why and when of deposit return schemes
Circular economy steps for plastic bottles and cans in England and Northern Ireland draws.
Join forces and share Building Safety knowledge in 2025
Why and how to contribute to the Building Safety Wiki.
Reporting on Payment Practices and Performance Regs
Approved amendment coming into effect 1 March 2025.