Headroom in buildings and other structures
Contents |
[edit] Introduction
In a building, headroom is the clear, vertical height (vertical clearance) which exists from the top surface of a floor to the underside of a:
Between two floors, the headroom is the clear vertical space between the two decks, from the top of the finished floor level of the lower deck, to the underside of the soffit of the upper deck. Low headroom may increase the likelihood of injury or the difficulty of manoeuvring large objects.
The headroom may or may not be sufficient to allow people to pass under easily. If not sufficient, it will not be possible to pass through without crouching or striking the top surface.
[edit] Stairs
On a flight of stairs, the headroom is the vertical distance between the pitch line (or nosing line) and the ceiling, taking into account any bulkheads. Approved Document K of the Building Regulations (section 1.11, diagram 1.3) stipulates a minimum headroom of 2m for all building types – whether on the stairs or on a landing.
[edit] Tunnels and bridges
Headroom may also refer to the clear, vertical height from a road’s top surface to the underside of a bridge or to the crown of a tunnel (or the ceiling of some buildings such as car parks). A sign indicating ‘low headroom’ warns that some vehicles may not be able to pass through without hitting the underside of the structure. In these cases, the clear height of the available headroom will be displayed, and there may be additional warning signs in advance of the low headroom or barriers to try to prevent impact.
[edit] Culverts and outflows
Culvert, screen and outfall manual, (CIRIA C786) published by CIRIA in 2019, defines headroom as the: ‘Vertical gap between the water surface and the roof (soffit) of a culvert or outfall to allow for floating debris (also known as air draught).’
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
The history of building regulations
A story of belated action in response to crisis.
Moisture, fire safety and emerging trends in living walls
How wet is your wall?
Current policy explained and newly published consultation by the UK and Welsh Governments.
British architecture 1919–39. Book review.
Conservation of listed prefabs in Moseley.
Energy industry calls for urgent reform.
Heritage staff wellbeing at work survey.
A five minute introduction.
50th Golden anniversary ECA Edmundson apprentice award
Showcasing the very best electrotechnical and engineering services for half a century.
Welsh government consults on HRBs and reg changes
Seeking feedback on a new regulatory regime and a broad range of issues.
CIOB Client Guide (2nd edition) March 2025
Free download covering statutory dutyholder roles under the Building Safety Act and much more.
AI and automation in 3D modelling and spatial design
Can almost half of design development tasks be automated?
Minister quizzed, as responsibility transfers to MHCLG and BSR publishes new building control guidance.
UK environmental regulations reform 2025
Amid wider new approaches to ensure regulators and regulation support growth.
The maintenance challenge of tenements.
BSRIA Statutory Compliance Inspection Checklist
BG80/2025 now significantly updated to include requirements related to important changes in legislation.