The components used to construct buildings are often fabricated, assembled or formed on site, often by hand, in conditions that may be less than ideal, and using materials with inherent ‘imperfections’. Whilst it is easy to draw a straight line on a drawing, to give an precise dimension, an exact mix or position it is impossible to construct, for example, concrete that is perfectly straight, simply by virtue of the inherent properties of the material itself.
It can be difficult therefore to determine whether a variation from perfection is simply a function of the nature of a particular type of construction or material, or whether it constitutes a defect. For this reason it is important to specify allowable variations, or ‘tolerances’, that are not considered to be defects.
The concept of tolerances is also be important when assembling a number of components, as some items may have very little flexibility to accommodate variations in neighbouring items. For example, it may be relatively straight forward to adjust the setting out of brickwork to accommodate a slight variation in the size of a timber beam, or simply to cut the beam on site, but if a double glazing unit is even a millimetre larger than the opening for which it is intended, it simply will not fit. Even when individual items appear to be reasonably close to what was specified, variations can accumulate when a number of components are assembled, and this can create a clash with an item that may have a low tolerance.
This is becoming more important as the number of items prefabricated off site has increased, and so there is less scope for changes on site to make things fit.
In addition to dimensions, tolerances may be used to specify allowable variations in strength, stability, the mix of a material, the performance of a system, temperature ranges and so on.
There are a thousands of different standards available setting out accepted classes and ranges of tolerance for different materials, components, systems, construction techniques, fabrication methods, installation techniques and building types. These may range from relatively large tolerances for site layouts or landscaping to very precise tolerances for manufactured components.
It is important that tolerances are clearly specified in contract documents and that they are properly understood by designers, fabricators, contractors and site supervisors.
NB Government Functional Standard, GovS 002: Project delivery; portfolio, programme and project management, Version: 2.0, published on 15 July 2021 by HM Government, defines tolerance as: ‘The permissible deviation above and below a plan’s target for time and cost without escalating the deviation to the next level of management. There can also be tolerance levels for quality, scope, benefit and risk. Tolerance is applied at project, stage and team levels.’
The BSRIA guide to 'Commissioning Air Systems' (BG 49/2024), written by by Keith Barker and published by BSRIA in March 2024, explains how to commission ducted air distribution systems in buildings. It was originally published in 2013, then 2015 with the latest update in 2024. It defines tolerance as: 'The permissible range of variation from the specified design value.'
[edit] Related articles on Designing Buildings
- Accuracy.
- Buildability.
- Building information modelling.
- Clash avoidance.
- Construction quality.
- Defects.
- Design coordination.
- Offsite manufacturing.
- Prefabrication.
- Precision.
- Quality control.
- Samples and mock-ups.
- Site inspection.
- Site inspector.
- Spacing.
- Specification.
- Testing construction materials.
- Types of drawing.
Featured articles and news
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Heat pumps, vehicle chargers and heating appliances must be sold with smart functionality.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
New-style degrees set for reformed ARB accreditation
Following the ARB Tomorrow's Architects competency outcomes for Architects.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.
Preserving, waterproofing and decorating buildings.
Many resources for visitors aswell as new features for members.
Using technology to empower communities
The Community data platform; capturing the DNA of a place and fostering participation, for better design.
Heat pump and wind turbine sound calculations for PDRs
MCS publish updated sound calculation standards for permitted development installations.
Homes England creates largest housing-led site in the North
Successful, 34 hectare land acquisition with the residential allocation now completed.
Scottish apprenticeship training proposals
General support although better accountability and transparency is sought.
The history of building regulations
A story of belated action in response to crisis.
Moisture, fire safety and emerging trends in living walls
How wet is your wall?
Current policy explained and newly published consultation by the UK and Welsh Governments.
British architecture 1919–39. Book review.
Conservation of listed prefabs in Moseley.
Energy industry calls for urgent reform.