Charring rate
Charring rate, refers to depth and speed that materials burn on exposure to fire. It is a key part of calculating the fire resistance of different timber elements in buildings, particularly structural elements. The charring rates are calculated by measuring the char depth, in comparison with the time material is exposed to the heat load.
EN 1995-1-2:2004 provides charring rates for different timber materials for the purposes of informing initial design. The charring rates apply to each face of the timber that is exposed to fire. For example, if a softwood element is exposed on all four of its sides to 20 minutes of fire: 2 x 20 x 0.8 = 32 mm
Example different material charring rates ßn (mm/min)
- Softwood timber 0.8
- Softwood glulam and laminated veneer lumber (LVL)0.7
- Western Red Cedar (390 kg/m³) 0.8
- Hardwood timber and hardwood glulam 0.55
- Oak and Sapele (>640 kg/m³) 0.5
It is important to note that the process of charring releases air and oxygen and chemically restructures timber to actually make it more fire resistant, this process can also be carried out mechanically where wood is burned evenly and at a constant rate to improve performance.
[edit] Related articles on Designing Buildings
Featured articles and news
The act of preservation may sometimes be futile.
Twas the site before Christmas...
A rhyme for the industry and a thankyou to our supporters.
Plumbing and heating systems in schools
New apprentice pay rates coming into effect in the new year
Addressing the impact of recent national minimum wage changes.
EBSSA support for the new industry competence structure
The Engineering and Building Services Skills Authority, in working group 2.
Notes from BSRIA Sustainable Futures briefing
From carbon down to the all important customer: Redefining Retrofit for Net Zero Living.
Principal Designer: A New Opportunity for Architects
ACA launches a Principal Designer Register for architects.
A new government plan for housing and nature recovery
Exploring a new housing and infrastructure nature recovery framework.
Leveraging technology to enhance prospects for students
A case study on the significance of the Autodesk Revit certification.
Fundamental Review of Building Regulations Guidance
Announced during commons debate on the Grenfell Inquiry Phase 2 report.
CIAT responds to the updated National Planning Policy Framework
With key changes in the revised NPPF outlined.
Councils and communities highlighted for delivery of common-sense housing in planning overhaul
As government follows up with mandatory housing targets.