Selection of Control Valves in Variable Flow Systems (BG 51/2014) written by Chris Parsloe and published by BSRIA in June 2014, defines a Three-port control valve (3PV) as: ‘An actuated control valve with three ports (usually two inlet and one outlet) which varies the flow through a terminal device by transferring a proportion of the flow through a separate piped bypass…. The majority of three-port valves used in HVAC are mixing valves and as such have two input ports and one output port. A few can be used as diverting valves with one input port and two output ports, but this is rare (except for rotary shoe type valves). As such, there is no ‘diverting’ port when used in most HVAC applications. Instead the mixing valve is installed on the return from a terminal device and as such is described as a ‘mixing valve used in a diverting application.’
It suggests that typical applications include; modulating control of heating or cooling outputs for air handling units, large fan coil units, and plate heat exchangers in constant flow branches.
--BSRIA
[edit] Related articles on Designing Buildings
Featured articles and news
HSE simplified advice for installers of stone worktops
After company fined for repeatedly failing to protect workers.
Co-located with 10th year of UK Construction Week.
How orchards can influence planning and development.
Time for knapping, no time for napping
Decorative split stone square patterns in facades.
A practical guide to the use of flint in design and architecture.
Designing for neurodiversity: driving change for the better
Accessible inclusive design translated into reality.
RIBA detailed response to Grenfell Inquiry Phase 2 report
Briefing notes following its initial 4 September response.
Approved Document B: Fire Safety from March
Current and future changes with historical documentation.
A New Year, a new look for BSRIA
As phase 1 of the BSRIA Living Laboratory is completed.
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from construction and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.