Flanking sound
Flanking sound (or flanking noise) is sound that transmits between spaces indirectly, going over or around, rather than directly through the main separating element. This can allow sound to transmit between spaces even though the main separating element itself provides good acoustic insulation.
Approved document E: Resistance to the passage of sound, defines ‘flanking transmission’ as, ‘Sound transmitted between rooms via flanking elements instead of directly through separating elements or along any path other than the direct path’. It defines a ‘flanking element’ as, ‘Any building element that contributes to sound transmission between rooms in a building that is not a separating floor or separating wall’.
A common example of flanking is sound transmitted between two spaces through a floor void (or even a floating screed) that runs under the separating partition, even though the partition provides good acoustic insulation preventing the direct transmission of sound.
Flanking can result from both impact sounds and airborne sounds.
Any building element that penetrates or circumnavigates a separating element can result in flanking. This might include:
- Windows and doors.
- Flanking ceilings, floors and walls which continue past the separating element into the adjoining space.
- Voids such as wall cavities, suspended ceilings and raised floors.
- Penetrating joists.
- Corridors and other circulation spaces.
- Ductwork and pipework.
- Sockets.
- Poor workmanship.
Flanking should be considered early in the design stage of new developments and detailing should eliminate or minimise the inadvertent downgrading of sound insulation. Junctions between elements in particular can offer a potential flanking route if they are not carefully detailed and constructed. Good briefing, supervision and inspection on site can help to ensure that the quality of workmanship remains high so that details are constructed as designed.
Flanking can be a particular issue where adjoining spaces have different uses, such as; a lecture theatre next to an office, a private room adjacent to a circulation space, or between neighbouring houses with different patterns of occupancy and behaviour.
Flanking can be difficult to treat in older buildings, where the addition of sound insulation to one element simply reveals a flanking path through another.
Approved document E of the building regulations: Resistance to the passage of sound, sets out requirements for sound insulation between spaces and provides guidance on how to detail separating elements to avoid flanking.
BS EN ISO 10848-4:2010 provides a standard for the laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms.
[edit] Related articles on Designing Buildings
- Airborne sound.
- Ash deafening.
- British standards.
- Building acoustics.
- Building Bulletin 93: acoustic design of schools.
- Decibel.
- Flanking element.
- Flanking transmission.
- Noise nuisance.
- Raised floor.
- Reverberation time.
- Sound absorption.
- Sound insulation.
- Sound v noise.
- Structure-borne sound.
- Suspended ceiling.
Featured articles and news
The restoration of the novelist’s birthplace in Eastwood.
Life Critical Fire Safety External Wall System LCFS EWS
Breaking down what is meant by this now often used term.
PAC report on the Remediation of Dangerous Cladding
Recommendations on workforce, transparency, support, insurance, funding, fraud and mismanagement.
New towns, expanded settlements and housing delivery
Modular inquiry asks if new towns and expanded settlements are an effective means of delivering housing.
Building Engineering Business Survey Q1 2025
Survey shows growth remains flat as skill shortages and volatile pricing persist.
Construction contract awards remain buoyant
Infrastructure up but residential struggles.
Home builders call for suspension of Building Safety Levy
HBF with over 100 home builders write to the Chancellor.
CIOB Apprentice of the Year 2024/2025
CIOB names James Monk a quantity surveyor from Cambridge as the winner.
Warm Homes Plan and existing energy bill support policies
Breaking down what existing policies are and what they do.
Treasury responds to sector submission on Warm Homes
Trade associations call on Government to make good on manifesto pledge for the upgrading of 5 million homes.
A tour through Robotic Installation Systems for Elevators, Innovation Labs, MetaCore and PORT tech.
A dynamic brand built for impact stitched into BSRIA’s building fabric.
BS 9991:2024 and the recently published CLC advisory note
Fire safety in the design, management and use of residential buildings. Code of practice.