Conoid shell
A conoid is a special kind of warped ruled surface which, as a curved shell roof, can be used as an alternative to a barrel vault. The basic principle is that one edge of the shell is curved while the opposite edge is kept straight. In architecture, this is referred to as a ‘right conoid’.
Two basic geometrical forms are encountered:
- A straight line is moved along a curved line at one end and a straight line at the other end, the resultant shape being cut to the required length.
- A straight line is moved along a curved line at one end and a different curved line at the other end.
The end consists of a reinforced concrete or steel lattice, which serves as a stiffening beam to prevent shell deformation. Support is required at all corners.
Spans of up to 12 m with chord lengths of up to 24 m are possible. The typical chord-to-span ratio is 2:1.
When conoids are made of reinforced concrete they require formwork on which to set the reinforcing steel and pour the concrete. The initial cost of making the formwork is usually high, but it can be reduced by pouring many shells on the same form.
There can be a solid infill or glazed end diaphragm. Glass panes set between adjacent conoids at the curved front of each conoid can allow for illumination. If the conoids face north they get the best natural light, which can be important for space such as factories.
Conoid shells are an ideal shape for cantilevered roofs covering the stands of stadiums with either a curvature up or a curvature down.
[edit] Find out more
[edit] Related articles on Designing Buildings Wiki
- Anticlastic.
- Barrel vault.
- Cantilever.
- Folded plate construction.
- Hyperbolic paraboloid.
- Long span roof.
- Megastructure.
- Pendentive dome.
- Portal frame.
- Shell roof.
- Suspended ceiling.
- Synclastic.
- Tensile structures.
- Types of ceiling.
- Types of dome.
- The history of fabric structures.
[edit] External references
- ‘Building Construction Handbook’ (6th ed.), CHUDLEY, R., GREENO, R., Butterworth-Heinemann (2007)
- ‘The story of a right wavelet conoid’ , J. Dolezal (2011)
Synclastic.
Featured articles and news
Specifying rendered external wall insulation for fire safety
How to interrogate the evidence provided to the specifier.
The benefits of writing articles for your organisation
How to create a profile for your organisation and publish for free.
No Falls Week. The importance of safe working at height
What to expect and what is on offer to avoid accidents.
Scottish Government action to reach net-zero targets
Retrofit expert group highlight critical actions needed.
A forward thinking, inclusive global community of members.
From engineered product life-spans, to their extension.
Circular economy in the built environment
A brief description from 2021. Where are we now?
Mental Health Awareness Week with ABS
Architects Benevolent Society programme of activity.
CLC publishes domestic retrofit competency framework
Roadmap of Skills for net zero.
May 13-19: Moving more for our mental health.
Understanding is key to conservation.
Open industry engagement survey seeks responses
Institutions and the importance of engagement.
National Retrofit Hub unveils new guide
Digital Building Logbooks and Retrofit: An Introduction.
Enhancing construction site reporting efficiency
Through digitisation and the digital revolution.