Drenchers
Drenchers are a system of water heads that are used for the fire protection. In contrast to sprinklers which are found internally, drenchers are normally found on the exterior of a building to protect against a fire from a neighbouring building. They tend to be positioned on roofs and over windows and external openings.
Another difference between sprinklers and drenchers is that all nozzles in the drencher system are activated simultaneously, whereas individual nozzles in a sprinkler system open when activated.
A drencher system consists of the follows components:
- Water source.
- Pump unit.
- Distribution piping.
- Control fittings.
- Alarm device.
- Special nozzles or water head.
The water heads are like those of sprinklers and may be sealed or unsealed.
The three main types of drenchers are:
- Roof drenchers: Positioned on the roof ridge and throw a curtain of water upwards.
- Wall or curtain drenchers: Throw a curtain of water over openings or portions of a building most likely to admit fire.
- Window drenchers: Positioned horizontally level with the top of a window so as to protect the opening.
[edit] Related articles on Designing Buildings Wiki
- Business Sprinkler Alliance.
- Case study A for offices to show where automatic sprinklers have the greatest impact.
- Design benefits of automatic sprinkler systems granted under approved document B.
- External fire spread, Supplementary guidance to BR 187 incorporating probabilistic and time-based approaches.
- Fire detection and alarm system.
- Fire in buildings.
- Fire safety design.
- Making the case for sprinklers and dispelling myths.
- Sprinkler.
- Sprinkler head.
- The impact of automatic sprinklers on building design.
Featured articles and news
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from constructuon and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.
The increasing costs of repair and remediation
Highlighted by regulator of social housing, as acceleration plan continues.
Free topic guide on mould in buildings
The new TG 26/2024 published by BSRIA.
Greater control for LAs over private rental selective licensing
A brief explanation of changes with the NRLA response.
Practice costs for architectural technologists
Salary standards and working out what you’re worth.
The Health and Safety Executive at 50
And over 200 years of Operational Safety and Health.
Thermal imaging surveys a brief intro
Thermal Imaging of Buildings; a pocket guide BG 72/2017.
Internally insulating a historical building
An experimental DIY approach using mineral thermal lime plaster.
Tree species selection for green infrastructure: A guide for specifiers.
The future of the Grenfell Tower site
Principles, promises, recommendations and a decision expected in February 2025.
Comments