Colour Rendering Index CRI
Comparing the Colour Rendering Index (CRI) of incandescent and LED lamps.
Contents |
[edit] Introduction
Colour can only be perceived due to the presence of light. Most light sources produce different wavelength combinations.
Visual light comprises a wide range of colours. This can be seen by using a prism to split it into its constituent parts. This range of colours is called a ‘spectrum’ and the colours, each with a different wavelength, are always in the same order, from red at one end through orange, yellow, green, blue, indigo to violet at the other end. Red light has a longer wavelength and blue shorter.
In reality, there are many, many different colours in the spectral range because it is seamless, as one colour gradually merges into the next. Each wavelength stimulates the cone cells (colour receptors) in the human eye in a different way to produce the sensation of colour. So, when we say that ‘the banana is yellow’, it would be more accurate to say a sensation of yellow is generated by an area of the retina (at the back of the eye) that corresponds to where light rays from the banana are being received.
[edit] Colour appearance
Colour appearance refers to the visual sensation correlated with the ‘warmth’ or ‘coolness’ of the light emitted by a lamp. There are a wide variety of different types of lamps available. These include filament lamps, discharge lamps (including fluorescent, xenon arc lamps and high intensity discharge or HID lamps), light-emitting diodes (LEDs) and so on. For more information, see Types of lamp.
Each type of lamp has an impact on colour appearance. The metric used to characterise the colour appearance of the light emitted by a light lamp is the correlated colour temperature (CCT), expressed in Kelvin (K). Warm white light is produced by lamps with a colour temperature below 3,000 K (reddish hues), whereas 4,000 K and above (bluish) is cool to cold.
In some instances, the colour of light can trigger certain behaviours. For instance, in outdoor applications, artificial light with bluish tones may have a disruptive impact on wildlife and plants that depend on warmer tones to maintain their circadian rhythm.
[edit] Colour rendering
BRE's 'The essential guide to retail lighting' notes, '...colour appearance is quite separate from the colour rendering of the lamp, which is the ability of a light source to show surface colours as they should be, usually in comparison with a tungsten or daylight source. Measured on the colour rendering index (CRI) scale. A value of 0 means it is impossible to discern colours at all, and a score of 100 means no colour distortion.’
CRI measures the output of lamps (artificial light) compared to natural light (daylight). It also calculates and analyses any colour that is reflected from an object that is illuminated by an artificial source.
[edit] CRI rating scale
90 - 100 | Excellent |
85 - 65 | Good (daylight) |
65 | Good (cool white light) |
55 | Poor (warm white light) |
50 - 0 | Poor |
A lamp’s spectrum determines its CRI. A low CRI can make it difficult to distinguish colour, so lamps that fall in this range are not ideal for installations where this characteristic is a priority. An incandescent lamp has a continuous spectrum, which means it should have a high CRI and will deliver a clear visual experience with little distortion.
The preferred CRI rating will relate to the mood or experience that is required in the area being lit. If the accuracy of colour is vital, a higher CRI rating should be selected. For most indoor lighting applications a CRI value of at least 80 is recommended, according to BRE.
LED lamps typically fail to register a CRI higher than 90. However, they have emerged as a popular replacement, especially in Europe, for incandescent and halogen lamps (which are disappearing from the marketplace).
CRI is a general term used to label the colour rendering characteristics of many commercial lighting products. However, the correct international term is the CIE Ra value, which is the international standard colour rendering index as determined by the International Commission on Illumination (or Commission internationale de l'éclairage, CIE).
[edit] Related articles on Designing Buildings Wiki
- Colour appearance.
- Colour temperature.
- Colour in the built environment.
- Commercial lighting.
- Daylight benefits in healthcare buildings.
- Daylight factor.
- Daylight lighting systems.
- Dichroic reflector.
- Discharge lamp.
- Extra-low voltage lamps.
- General lighting v task lighting.
- Illuminance.
- Lamps.
- Lamp efficacy.
- LED lights.
- Lighting.
- Lighting for circadian rhythms.
- Lighting of construction sites.
- Light Pollution - Human Health Impacts from LEDs.
- Luminaire efficacy.
- The Anatomy of Colour.
- Types of lamp.
Featured articles and news
Twas the site before Christmas...
A rhyme for the industry and a thankyou to our supporters.
Plumbing and heating systems in schools
New apprentice pay rates coming into effect in the new year
Addressing the impact of recent national minimum wage changes.
EBSSA support for the new industry competence structure
The Engineering and Building Services Skills Authority, in working group 2.
Notes from BSRIA Sustainable Futures briefing
From carbon down to the all important customer: Redefining Retrofit for Net Zero Living.
Principal Designer: A New Opportunity for Architects
ACA launches a Principal Designer Register for architects.
A new government plan for housing and nature recovery
Exploring a new housing and infrastructure nature recovery framework.
Leveraging technology to enhance prospects for students
A case study on the significance of the Autodesk Revit certification.
Fundamental Review of Building Regulations Guidance
Announced during commons debate on the Grenfell Inquiry Phase 2 report.
CIAT responds to the updated National Planning Policy Framework
With key changes in the revised NPPF outlined.
Councils and communities highlighted for delivery of common-sense housing in planning overhaul
As government follows up with mandatory housing targets.
CIOB photographic competition final images revealed
Art of Building produces stunning images for another year.
HSE prosecutes company for putting workers at risk
Roofing company fined and its director sentenced.
Strategic restructure to transform industry competence
EBSSA becomes part of a new industry competence structure.
Major overhaul of planning committees proposed by government
Planning decisions set to be fast-tracked to tackle the housing crisis.
Industry Competence Steering Group restructure
ICSG transitions to the Industry Competence Committee (ICC) under the Building Safety Regulator (BSR).
Principal Contractor Competency Certification Scheme
CIOB PCCCS competence framework for Principal Contractors.
The CIAT Principal Designer register
Issues explained via a series of FAQs.