Dry-bulb temperature
Dry-bulb temperature (Tdb, DBT or Td), is a measure of air temperature. It is referred to as dry-bulb temperature because the thermometer bulb is dry and so the temperature recorded does not vary with the moisture content of the air. This is as opposed to wet-bulb temperature which is the temperature recorded by a thermometer that has its bulb wrapped in cloth and moistened with distilled water. Wet-bulb temperatures are the same as dry-bulb temperatures at a relative humidity of 100%, but otherwise wet-bulb temperatures will be lower than dry-bulb temperatures due to the cooling effect of evaporation (described as wet-bulb depression).
A sling psychrometer holds both wet and dry-bulb thermometers and can be used to express the physical and thermal properties of moist air on a psychrometric chart.
Dry-bulb temperature can be measured by a thermometer exposed to the air but shielded from radiation and moisture. It can be expressed in Celsius (C), Fahrenheit (F) or Kelvin (K).
Dry-bulb temperature can be used as to express a component of thermal comfort. For example, the wet bulb globe temperature index (WBGT) is widely used for the assessment of heat stress and combines wet-bulb temperature, dry-bulb temperature and globe temperature (mean radiant temperature).
[edit] Related articles on Designing Buildings
Featured articles and news
Top 50 firms awarded 52bn of projects in the last year
New engineering data shows.
Enhancing construction site reporting efficiency
Through digitisation and the digital revolution.
Noise in the built environment
BSRIA guide TG 20/2021.
17,000 people suffer conditions as a result of exposure to excessive noise at work.
Turning down the noise: Auditory health
A pervasive risk with far-reaching consequences.
UK Construction Week, London is here !
Debuting major international pavilions and much more.
Getting the most out of heat pumps and heating
How heat pumps work and how they work best.
Plumbing and heating for successful retrofit and renovation
Low temperature underfloor systems and heat pumps.
Cost-of-living crisis and home improvement plans
Starting on the right footing and top tips for projects.
Delays on construction projects
Types, mitigation and the acceleration of works.
From Chaucer to Fawlty Towers.
Electrotechnical excellence, now open for entries.
Net zero electricity grids BSRIA guide NZG 5/2024
Outlining the changes needed to transition to net zero.
CIOB Global Student Challenge 2024
Universitas Indonesia wins for second year running.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.