Weather louvres can combat and complement the effects of climate change
![]() |
Contents |
[edit] Introduction
When it comes to the efficient operation of a building, even the seemingly small decisions can have a big consequence. For example, what elements do you need to consider when specifying a weather louvre? BSRIA North’s expert, louvre-testing facilities offer a solution.
A weather louvre is a passive device, essentially a grille fixed over an opening, designed to let air through and keep water out. It is designed to perform both these functions concurrently and its suitability for a specific application is established by how effectively it achieves these functions in combination.
[edit] June Davis, Business Manager, BSRIA North, said:
“Weather louvres are big business and BSRIA can offer many hints and tips. Failure to understand and clearly express the performance requirement at the design or procurement stage increases the risk of the product not being fit for purpose. The end user may experience unwanted water penetration or wasted energy. This certainly isn’t a green approach. And, just as crucially for BSRIA members, does it save money?”
[edit] To achieve optimum performance, system designers and specifiers of weather louvres must have an appreciation of:
- How to understand weather louvre requirements;
- How to minimise whole-life costs through system design and louvre selection;
- Which terms to use to ensure that performance data are consistently stated when sourcing products from suppliers:
- How to minimise risks associated with overstated performance claims, and
- Performance testing
The standard performance tests for weather louvres are described in BS EN 13030:2001 Ventilation for Buildings -Terminals - Performance testing of louvres subjected to simulated rain and BS EN 13181:2001 Ventilation for Buildings - Terminals - Performance testing of louvres subject to simulated sand.
June Davis continued:
“The test methods are designed to simulate real-life operating conditions the louvre will undergo when installed. The rejection performance can be established for a range of ventilation rates while subjected to windblown rain or sand.
"BSRIA operates a specialist weather-louvre test facility, which offers members and clients alike independent performance testing of weather louvres to these standards.
Indeed, it’s a niche and unique operation and facility. We are often asked questions by members about louvres and, specifically, increasing the quantity of the air flow through the louvre.”
[edit] Specifying a weather louvre
To specify a weather louvre usefully requires the following elements:
- Understanding of the required volume flow rate, louvre face area and subsequent face velocity;
- Understanding of the permissible water penetration for the application, based on the classes provided by the standard test (A-D), and
- Understanding of the standard test classes for discharge or entry loss coefficient (1-4) and that a higher Cd means lower energy usage.
June Davis added:
“It must, however, be mentioned that other factors can affect the running and performance of a weather louvre which are not accounted for by the standard test.”
If you are looking for further information visit www.bsria.co.uk where you can download BSRIA’s Weather Louvre Specification Guide (BG 36/2012) for FREE or for louvre testing enquiries either contact 01772 754 381 or email: [email protected]
[edit] About this article
This article was provided by BSRIA and appeared origianlly on its website in June 2019.
BSRIA is a non-profit distributing, member-based association providing specialist services in construction and building services. More information at www.bsria.co.uk.
Other articles by BSRIA can be seen here.
[edit] Related articles on Designing Buildings Wiki
- Air infiltration testing.
- Approved Document F.
- BREEAM Potential for natural ventilation.
- BREEAM Visual comfort Glare control.
- Building services.
- Condensation.
- Curtain wall systems.
- Daylight lighting systems.
- Humidity.
- Interstitial condensation.
- Louvre (louver).
- Louvre specifications.
- Mechanical ventilation.
- Natural ventilation.
- Passive building design.
- Rainscreen
- Solar shading.
- Stack effect.
- Thermal comfort.
- Ventilation.
--BSRIA
Featured articles and news
The Architectural Technology Awards
The AT Awards 2025 are open for entries!
ECA Blueprint for Electrification
The 'mosaic of interconnected challenges' and how to deliver the UK’s Transition to Clean Power.
Grenfell Tower Principal Contractor Award notice
Tower repair and maintenance contractor announced as demolition contractor.
Passivhaus social homes benefit from heat pump service
Sixteen new homes designed and built to achieve Passivhaus constructed in Dumfries & Galloway.
CABE Publishes Results of 2025 Building Control Survey
Concern over lack of understanding of how roles have changed since the introduction of the BSA 2022.
British Architectural Sculpture 1851-1951
A rich heritage of decorative and figurative sculpture. Book review.
A programme to tackle the lack of diversity.
Independent Building Control review panel
Five members of the newly established, Grenfell Tower Inquiry recommended, panel appointed.
Welsh Recharging Electrical Skills Charter progresses
ECA progressing on the ‘asks’ of the Recharging Electrical Skills Charter at the Senedd in Wales.
A brief history from 1890s to 2020s.
CIOB and CORBON combine forces
To elevate professional standards in Nigeria’s construction industry.
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Heat pumps, vehicle chargers and heating appliances must be sold with smart functionality.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
New-style degrees set for reformed ARB accreditation
Following the ARB Tomorrow's Architects competency outcomes for Architects.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.