Stair design
In designing staircases, in particular residential work, thought must be given to access for furniture. Spiral staircases for instance are a real problem for bedroom furniture and windows may not have big enough openings for alternative access.
The regulations regarding stair width for communal stairs in blocks of flats is so confusing.
Starting with Part M, section M4(1) paragraph 1.12 says:
1.12 The principal communal stairs that give access to the dwelling should comply with one of the following:
- Where the dwelling is on an upper floor and does not have lift access, the stair meets the requirements of Part K for a general access stair.
- Where the dwelling is on an upper floor and does have lift access, the stair meets the requirements of Part K for a utility stair.
However, if we go to Part K, section 1, there is no specification of stair width for communal stairs in blocks of flats. Under “Width of flights of stairs” we only have two options:
For buildings other than dwellings
1.14 For stairs that form part of means of escape, refer to Approved Document B: Fire safety, Volume 2 – Buildings other than dwelling houses.
1.15 For flights of stairs which do not form part of the means of escape, provide all of the following.
- A minimum stair width between enclosing walls, strings or upstands of 1200mm.
- A minimum width between handrails of 1000mm.
For dwellings
1.16 In exceptional circumstances where severely sloping plots are involved, a stepped change of level within the entrance storey may be unavoidable. In those instances ensure that stairs within the entrance storey of a dwelling have flights with a minimum stair width of 900mm.
So paragraph 1.14 refers us to Part B, and under Part B Means of Escape from Flats, Width of common stairs, it says:
2.33 A stair of acceptable width for everyday use will be suf cient for escape purposes, but if it is also a fire-fighting stair, it should be at least 1100mm wide (see Appendix C for measurement of width).
So we know from Appendix C that stair width in Part B is defined as being "clear width between the walls or balustrades”.
But, the question is, what is an "acceptable width for everyday use”?
--Needleandmortar 11:25, 11 Aug 2017 (BST)
To muddy the waters a little more there's Part K1 paragraph 1.18 which is headed up "For buildings other than dwellings and common access areas in buildings that contain flats". Now, does that mean "other than common access areas in buildings that contain flats" or does it mean "for common access areas in buildings that contain flats". I interpret it as the former.
--Needleandmortar 11:40, 11 Aug 2017 (BST)
You must sign in or register to edit or comment on an article
Return to Talk:Stair design.
Featured articles and news
Specifying rendered external wall insulation for fire safety
How to interrogate the evidence provided to the specifier.
The benefits of writing articles for your organisation
How to create a profile for your organisation and publish for free.
No Falls Week. The importance of safe working at height
What to expect and what is on offer to avoid accidents.
Scottish Government action to reach net-zero targets
Retrofit expert group highlight critical actions needed.
A forward thinking, inclusive global community of members.
From engineered product life-spans, to their extension.
Circular economy in the built environment
A brief description from 2021. Where are we now?
Mental Health Awareness Week with ABS
Architects Benevolent Society programme of activity.
CLC publishes domestic retrofit competency framework
Roadmap of Skills for net zero.
May 13-19: Moving more for our mental health.
Understanding is key to conservation.
Open industry engagement survey seeks responses
Institutions and the importance of engagement.
National Retrofit Hub unveils new guide
Digital Building Logbooks and Retrofit: An Introduction.
Enhancing construction site reporting efficiency
Through digitisation and the digital revolution.